The fraction of tracer molecules taken up by myocytes on the first pass through a capillary is shown at different flows and for six tracers. In the second step a short-axis image of a stenosed and a normal region changes as stress flow rises in the normal region; the plateau of the flow–uptake curves reduces defect contrast.

Continuous stream · no seeking

Key idea: uptake is flow × extraction; extraction falls with flow, so uptake plateaus at high flow and the defect looks milder than it is; the relation is most linear for O-15 water and N-13 ammonia.

Source: book (14.1: first-pass extractions; plateau at 2-2.5× for Tl-201, ~2× for Tc-99m). Curves are fitted to these values with an extended Renkin–Crone model (PS rises with flow); representative. The 1.5× flow limit in the stenosed region is an example value.

How to use: a single click on the drawing pauses and resumes; ↑ ↓ change the flow level in the first step and the tracer in the second (you can also tap a tracer row); ← → change steps.

Did this animation help you understand the topic?