Left, an anterior dynamic scintigraphy frame (black background, white counts); centre, trunk and bowel anatomy; right, the three criteria of active bleeding; below, a strip of dynamic frames. In the first step only the blood pool is seen. In the second a new focus appears in the ascending colon and intensifies; this first appearance is the bleeding site. In the third blood moves forward in the large bowel and the leading collection becomes the most intense; in the small-bowel example activity moves centrally, curvilinearly and rapidly. The fourth step shows three pitfalls: a fixed focus, free pertechnetate in the stomach (thyroid and salivary glands in the neck), and the first frame of a delayed study. The fifth compares the lowest bleeding rates detectable by scintigraphy, CT angiography and conventional angiography on a logarithmic scale.

Continuous stream · no seeking

The bleeding site is where activity first appears, not the most intense or largest focus. Active bleeding needs all three criteria: activity outside the blood pool, intensity change on consecutive frames and movement conforming to bowel.

Source: book 18.6; SNMMI/ACNM GI bleeding scintigraphy guideline 3.0 (Dam et al., J Nucl Med Technol 2025;53:14-23): three criteria, site of first appearance, antegrade/retrograde movement, small and large bowel patterns, frame duration, pitfalls, scintigraphy 0.04 mL/min (experimental) and 0.1 mL/min (clinical). CT angiography: Kuhle and Sheiman, Radiology 2003;228:743 (swine model, 0.3 mL/min). Conventional angiography 0.5-1.0 mL/min (book). Anatomy from the trunk atlas; example case, times representative.

Use: a single click on the drawing pauses and resumes; ← → change steps; in the third step ↑ ↓ or the buttons change the example; clicking a frame in the strip jumps to that minute.

Did this animation help you understand the topic?

GI bleeding scintigraphy: where it first appears · Open in Nuclear Medicine Explained ↗