Neck MIBI images are shown early and as time passes; thyroid washout and adenoma retention are traced on a remaining-activity curve, with rapid-washout and MIBI-avid nodule scenarios. The second step subtracts a scaled pertechnetate image from the MIBI image and shows the result of correct, under- and over-scaling.
Step 1/2
Dual phase: differential washout
Tc-99m MIBI is taken up early (10-15 min) by both the thyroid and a parathyroid adenoma. The thyroid washes MIBI out faster; on the late image at 90-150 min the adenoma retains it and stands out. A rapidly washing adenoma gives a false negative, a MIBI-avid thyroid nodule (e.g. oncocytic adenoma) a false positive. Change the finding.
Key idea: dual phase relies on differential washout between thyroid and adenoma, subtraction on a second agent taken up by the thyroid only; each has its own false results.
Source: book (13.3: early 10-15 min, late 90-150 min — EANM 2021, differential washout; rapid washout → false negative; MIBI-avid thyroid nodule → false positive; MIBI − pertechnetate/I-123 subtraction, misregistration). Images and washout rates are representative (left at 180 min: thyroid ~30%, adenoma ~85%); each image is scaled to its own maximum.
How to use: ↑ ↓ or the buttons below change the scenario in the first step and the subtraction scale in the second; in the first step a single click on the drawing pauses and resumes; ← → change steps.
MIBI parathyroid imaging: dual phase and subtraction · Open in Nuclear Medicine Explained ↗