How many photons from a source reach a worker depends on distance, time and lead shielding; the shielding order and bremsstrahlung for a beta source are shown.
Step 1/5
Distance: inverse square law
Photons spread out from the source in all directions; with distance the same number of photons covers a larger area. Dose rate is inversely proportional to the square of distance: Ḋ₁·d₁² = Ḋ₂·d₂². Doubling the distance cuts dose 4-fold, tripling it 9-fold. That is why long tongs and remote injection work.
Example: 20 mCi (740 MBq) source. Γ (R·cm²/mCi·h) and lead HVL from the book: Tc-99m 0.78 / 0.3 mm, I-131 2.17 / 3 mm, F-18 5.7 / 4 mm. Ẋ = Γ·A/d² applies to a point source; body attenuation and scatter are not included. Photons are generated in random 3D directions; hits on the body fall as 1/d².
Key point: dose rate falls with the square of distance, dose rises in proportion to time, and each HVL of lead halves the photons passing; a beta source is shielded first with low-Z material.
Source: book (Γ Tc-99m 0.78, I-131 2.17, F-18 5.7 R·cm²/mCi·h; lead HVL 0.3 / 3 / 4 mm); example 20 mCi (740 MBq) point source, body attenuation and scatter not included. Beta step: P-32 Emax 1.711 MeV (ENSDF), range NIST ESTAR, bremsstrahlung fraction Cherry, Sorenson & Phelps (Physics in Nuclear Medicine). Magnifier: Rutherford scattering; bremsstrahlung spectrum and angular distribution after Bethe–Heitler (Attix, Introduction to Radiological Physics and Radiation Dosimetry); atomic radii not to scale.
How to use: press and drag the worker (release and it moves back and forth on its own); hold ← → to change the distance smoothly; one click on the drawing pauses and resumes, double-click enlarges.
Radiation protection: time, distance, shielding · Open in Nuclear Medicine Explained ↗