Validation and versions
For each tool: the guidelines and data it is based on, how it was validated, its limits and its review status. The tools are monitored every week for changes in their sources and fully reviewed every three months; medical changes are approved by a physician, physics changes by a medical physicist.
Study Centre
- Version
- 2.0
- Last change
- Last review
- · next
- Review
- awaiting physician review
How it was validated
- Statistics were compared with published datasets: logistic regression (Challenger data, b₁ −0.2322), paired t and Wilcoxon (sleep data), Pearson (Anscombe, r 0.8164), Mann–Whitney and Fisher exact tests; Cox and log-rank with the Gehan leukaemia data.
- IBSI texture and shape features match the consortium consensus values on the digital phantom, 178/178.
- DICOM SEG and RTSTRUCT round-trip test Dice 1.000; browser tests at desktop and 375 px phone width.
Sources
- Cox DR 1972; Breslow NE 1974; Harrell FE et al. Stat Med 1996;15:361-87 (Cox, c-index, bootstrap)
- Peduzzi P et al. J Clin Epidemiol 1996; Riley RD et al. BMJ 2020;368:m441 (EPV, sample size)
- Benjamini Y, Hochberg Y. J R Stat Soc B 1995;57:289-300
- Koo TK, Li MY. J Chiropr Med 2016;15:155-63 (ICC)
- Zwanenburg A et al. Radiology 2020;295:328-38 (IBSI)
- Collins GS et al. BMJ 2024;385:e078378 (TRIPOD+AI)
Limits
- Images and patient data never leave the browser; the only permanent record is a password-encrypted file. The adviser box does not replace a statistician.
Dose calculators
- Version
- 1.0
- Last change
- Last review
- · next
- Review
- awaiting physician and medical physicist review
- Guideline currency check
How it was validated
- Values were compared line by line with the book's own tables (Quick Review, Chapters 10 and 26) and the source card.
Sources
- EANM Paediatric Dosage Card (version 5.7.2016)
- IAEA LiveChart of Nuclides / ENSDF (yarı ömürler / half-lives)
- Boellaard R et al. [18F]FDG PET/CT: EANM procedure guidelines for tumour imaging, version 3.0. EANM J 2025. doi:10.1016/j.eanmj.2025.100006 (2015 v2.0 yerine / replaces v2.0, 2015)
- EANM radioiodine therapy guidance (Graves / benign thyroid disease)
Limits
- For education; for a real patient the activity is set by the institution's protocol and the physicist.
Report templates
- Version
- 0.2
- Last change
- Last review
- · next
- Review
- awaiting physician review
- Guideline currency check
How it was validated
- Items were drawn from the reporting sections of the guidelines in original wording; references and DOIs were verified in PubMed. The template assigns no category; the physician chooses.
Sources
- Bozkurt MF et al. EANM/SNMMI guideline for Ga-68 DOTA-peptide and F-18 DOPA PET/CT 2017
- Werner RA et al. SSTR-RADS 1.0. J Nucl Med 2018
- Wahl RL et al. PERCIST 1.0. J Nucl Med 2009;50:122S
- İlgili EANM/SNMMI kılavuzlarının raporlama bölümleri (şablon başına künye sayfada) / the reporting sections of the relevant guidelines (reference per template on the page)
Limits
- Draft version; awaiting expert approval. The report text never goes to a server.
TARE (Y-90 / Ho-166) dosimetry
- Version
- 1.0
- Last change
- Last review
- · next
- Review
- awaiting physician and medical physicist review
- Guideline currency check
How it was validated
- Single-compartment, partition model and lung dose formulas were compared with the source tables and unit tests (tare, tare-goruntu).
Sources
- Weber M et al. EANM procedure guideline for intra-arterial radioactive compounds. Eur J Nucl Med Mol Imaging 2022;49:1682-99. doi:10.1007/s00259-021-05600-z
- Levillain H et al. International recommendations for personalised SIRT with Y-90 resin microspheres. Eur J Nucl Med Mol Imaging 2021;48:1570-84
- Chiesa C et al. EANM dosimetry committee SOP. EJNMMI Phys 2021;8:77
- Busse NC et al. AAPM MPPG 14.a. J Appl Clin Med Phys 2024
Limits
- For education and research, not clinical decision support. Moving glass microspheres to the 2025 international consensus awaits the editor's decision.
Image analysis (DICOM)
- Version
- 1.2
- Last change
- Last review
- · next
- Review
- awaiting medical physicist review
How it was validated
- PET/CT fusion, SUV and MTV/TLG were tested with sample DICOM series; IBSI features 178/178 on the digital phantom; compressed transfer syntaxes (JPEG, JPEG-LS, JPEG 2000, RLE, Deflate) with sample files.
Sources
- DICOM PS3.3 C.7.6.2.1.1 (geometri / geometry), PS3.15 Annex E (anonimleştirme / de-identification)
- Wahl RL et al. PERCIST 1.0. J Nucl Med 2009
- Driessen J et al. J Nucl Med 2022 (MTV yöntemleri / MTV methods)
- Zwanenburg A et al. IBSI. Radiology 2020;295:328-38
Limits
- Tilted gantry and multi-frame single-file volumes are not supported. Not a clinical diagnostic tool.
Academic tools
- Version
- 1.3
- Last change
- Last review
- · next
- Review
- completed
- Guideline currency check
How it was validated
- Every function is checked against published example data (academic validation script): Cox Rx β 1.509, SE 0.410; log-rank χ² 16.79.
Sources
- Chow SC, Shao J, Wang H. Sample Size Calculations in Clinical Research, 3rd ed., 2017
- Fleiss JL, Levin B, Paik MC. Statistical Methods for Rates and Proportions, 3rd ed., 2003
- Cohen J 1960 (kappa); Bland JM, Altman DG 1986
- Kleinbaum DG, Klein M. Survival Analysis, 3rd ed. (Gehan verisi / data)
Limits
- Numbers are for planning research; a statistician's opinion is recommended for final decisions.
- The poster's "Draft from abstract" button uses Claude: only the pasted abstract is sent; every number in the draft is checked against the abstract and a section with a number not in the abstract is not shown. The draft does not replace the author's reading.
Dosimetry simulator
- Version
- 1.0
- Last change
- Last review
- · next
- Review
- awaiting medical physicist review
- Guideline currency check
How it was validated
- Time-activity curve fitting and cumulated activity were compared with hand-calculated examples; sample cases are representative.
Sources
- ICRP Publication 107 (Lu-177 ortalama elektron enerjisi / mean electron energy)
- ICRP Publication 89 (referans organ kütleleri / reference organ masses)
- MIRD şeması (kitap Bölüm 10.2 / book Chapter 10.2)
Limits
- Local absorption assumption: photon contribution and organ-to-organ cross-dose are neglected (stated on the page).
Exams and events calendar
- Version
- 1.0
- Last change
- Last review
- · next
- Review
- verified against official sources (no medical content)
How it was validated
- Every exam, event and programme entry was compared with the organiser's official page; if a date has not been announced it is left blank, never estimated. Past entries are removed.
- An entry can be shown to several countries or regions; the country filter was tested with each entry's scope.
Sources
- Düzenleyici kurumların resmî sayfaları (her kayıtta bağlantı ve son kontrol günü) / the organisers' official pages (link and last check date on every entry)
Limits
- No automatic scanning yet: entries are updated by hand. Check the date on the official page before applying.
If you see an error or a more recent source, report it with the feedback button at the bottom of the page; corrections verified against a source are recorded here and in What's new.