Clinical applications · 2 steps
GFR by plasma sampling
Clearance is dose / area under the curve; the slope-intercept method misses the early distribution component, overestimates GFR and is corrected with Brøchner-Mortensen.
A GFR agent is injected into one arm and tubes are taken from the other arm at 120, 180 and 240 minutes; the area under the plasma concentration curve fills and clearance is computed as dose / area. In the second step the slope and intercept are drawn from the late samples on a log scale, the early area left out is shown, and the Brøchner-Mortensen correction is applied.
Key idea: clearance is dose / area under the curve; the slope-intercept method misses the early distribution component, overestimates GFR and is corrected with Brøchner-Mortensen.
Source: book (16.4: clearance = dose / area, slope-intercept with 2-4 samples, sampling from the other arm, Brøchner-Mortensen correction, Cr-51 EDTA, Tc-99m DTPA, when not to sample). Correction formula Brøchner-Mortensen 1972 (adults): Cl = 0.990778·Cl₁ − 0.001218·Cl₁². Dose and curve values are representative.