Clinical applications · 2 steps

GFR by plasma sampling

Clearance is dose / area under the curve; the slope-intercept method misses the early distribution component, overestimates GFR and is corrected with Brøchner-Mortensen.

A GFR agent is injected into one arm and tubes are taken from the other arm at 120, 180 and 240 minutes; the area under the plasma concentration curve fills and clearance is computed as dose / area. In the second step the slope and intercept are drawn from the late samples on a log scale, the early area left out is shown, and the Brøchner-Mortensen correction is applied.

Continuous stream · no seeking

Key idea: clearance is dose / area under the curve; the slope-intercept method misses the early distribution component, overestimates GFR and is corrected with Brøchner-Mortensen.

Source: book (16.4: clearance = dose / area, slope-intercept with 2-4 samples, sampling from the other arm, Brøchner-Mortensen correction, Cr-51 EDTA, Tc-99m DTPA, when not to sample). Correction formula Brøchner-Mortensen 1972 (adults): Cl = 0.990778·Cl₁ − 0.001218·Cl₁². Dose and curve values are representative.

How to use: a single click on the drawing pauses and resumes; drag the time bar below to any moment; ← → change steps.

Did this animation help you understand the topic?

Presentation mode ↗The animation alone, sized for full screen; for projecting in lectures and talks. ← → step, space plays/pauses.

Embed

Paste this code into your own page (course site, slides, learning platform). The animation arrives working, with its source written underneath.

Stage

In the book

In the book this animation runs in place of these figures: