传能线密度、相对生物效应与氧增强比

当LET接近约100 keV/µm时,电离间距接近DNA直径,双链断裂和RBE增加,氧效应减弱;LET更高时能量被浪费(过度杀伤,overkill)。

标题和摘要为机器辅助翻译(草稿);动画内容为英文。 英文完整页面 →

Ionisations left by radiations of different LET as they cross DNA, at nanometre scale; the change of RBE and OER with LET is shown.

Continuous stream · no seeking

Key point: as LET approaches about 100 keV/µm, ionisations become as close as the DNA diameter, double-strand breaks and RBE rise and the oxygen effect falls; at higher LET energy is wasted (overkill).

Source: LET values IAEA Radiobiology handbook; RBE and OER curves based on Barendsen 1968 (Hall and Giaccia), RBE axis qualitative; ionisation spacing schematic.

How to use: click or drag on the right-hand chart to change LET continuously; ← → change it step by step; the buttons below pick preset radiations; Space pauses and resumes.