Radiopharmacy · 2 of 8

Tc-99m kit preparation and labelling (general)

Awaiting physician review

To label a lyophilised kit with sodium pertechnetate (Tc-99m) under aseptic conditions and make the radiopharmaceutical ready for patient doses.

What you need

  • Kit vial and its product information (SmPC/package insert)
  • Tc-99m eluate with acceptable elution records
  • Vial shield, shielded syringe, sterile needles
  • Alcohol swab, gloves
  • If needed, a boiling water bath or heating block (shielded)
  • Dose calibrator, label, record form, QC materials

Steps

  1. Read the product information: the maximum activity and volume, the maximum age of the eluate, the heating or incubation time, the shelf life and the RCP method differ between kits.
  2. Calculate the activity required: patient doses at the time of use plus an allowance for decay; do not exceed the product's maximum activity and volume.
  3. Remove the kit cap, swab the stopper with alcohol and let it dry; place the vial in its labelled shield.
  4. Draw up the eluate in a shielded syringe; add it aseptically to the vial and, without removing the needle, withdraw an equal volume of gas to equalise pressure (unless the product information says otherwise).
  5. Mix as the product information specifies (gentle inversion for some kits, vigorous shaking for others), then incubate at room temperature for the stated time or heat in a shielded boiling water bath.
  6. Let a heated kit cool in its shield; inspect the solution from behind a shield (particles, discoloration; a suspension is expected for MAA).
  7. Assay the vial in the dose calibrator; label it with the radiopharmaceutical, activity, volume, time, expiry and the preparer's name.
  8. Measure RCP by the product's method (ITLC card); do not use the kit if it is below the limit. Record the result.

Key points

  • Pertechnetate is reduced by the stannous ion (Sn²⁺) in the kit and binds to the ligand. Oxidants (air, hypochlorite, peroxide) consume the tin and raise free pertechnetate; this is why vials are under nitrogen and excess air is not introduced.
  • Some kits need fresh eluate: for example, one HMPAO product requires eluate less than 2 hours old from a generator eluted within the previous 24 hours, and one MAG3 product at most 6 hours after elution.
  • Heated vials can crack; the bath must be shielded and the stopper kept above the water level.
  • Kit-specific values are in the table below and differ between products; the product information of the kit in use applies.

Kits: preparation and radiochemical purity

KitRCP (method, limit)Shelf life
Sestamibi (MIBI)
Preparation

1-3 mL eluate (Technescan: max 11.1 GBq); shake vigorously 5-10 times; heat upright in a shielded boiling water bath for 10 min (timing starts when the water returns to the boil; stopper above the water); cool 15 min

Product: Technescan MIBI (AB SmPC); Stamicis (AU PI 2026); Draximage Sestamibi (CA 2025); Ph. Eur. (PMC6166199)

Al₂O₃ TLC, ethanol; Ph. Eur., Technescan and Stamicis ≥ 94%; Draximage ≥ 90%Draximage: within 6 hours (15-25 °C)
Tetrofosmin
Preparation

4-8 mL diluted eluate; shake to dissolve; 15 min at room temperature; aluminium in the eluate must be below 5 ppm

Product: Myoview (UK SmPC 2024); Ph. Eur. (PMC6166199)

Ph. Eur. ≥ 90% (ITLC-SG, acetone-dichloromethane 35:65)12 hours after preparation (below 25 °C)
MAG3 (mertiatide)
Preparation

eluate at most 6 hours after elution, free of oxidants; mix and place in the boiling water bath within 5 min; 10 min at a continuous rolling boil; cool ~15 min

Product: Technescan MAG3 (ABD prospektüsü 2025; AU MIMS)

≥ 90% (Sep-Pak C18 method)6 hours after preparation
HMPAO (exametazime)
Preparation

eluate less than 2 hours old from a generator eluted within the previous 24 hours; 0.37-1.11 GBq in 5 mL

Product: Ceretec (UK SmPC 2023); EANM 2019; Ph. Eur. (PMC6166199)

≥ 80% (lipophilic complex; two systems: saline and MEK)unstabilised 30 min; stabilised with cobalt chloride 4 hours; only unstabilised for leucocyte labelling
MDP / HDP (diphosphonate)
Preparation

medronate (Kvaternik 2020 table): 2-5 mL, 3-6 GBq, 15 min at room temperature

Product: Technescan HDP (ABD prospektüsü 2025); Kvaternik ve ark., J Nucl Med Technol 2020;48:168-173 (doi 10.2967/jnmt.119.235432); Ph. Eur. (PMC6166199)

oxidronate Ph. Eur. ≥ 95% (ITLC-SG, sodium acetate and MEK)HDP: 8 hours after labelling (20-25 °C)
MAA (macroaggregated albumin)
Preparation

mix by gentle inversion in the shield, do not shake (foam); let stand 15 min for maximum binding; the activity to add is calculated from the particles per vial and the particles to be given (Medi-MAA: 3-8 × 10⁶ particles per vial, more than 90% 10-100 µm)

Product: Draximage MAA (FDA etiketi 2023); Medi-MAA (AB SmPC 2022); NANP 2016; Ph. Eur. (PMC6166199)

≥ 90% bound (Ph. Eur.: 3 µm filtration)in the product information (8 hours for one Draximage batch; NANP: 6 hours for a reduced-particle preparation)
DMSA (succimer)
Preparation

Renocis: 1-6 mL eluate, max 3.7 GBq (total volume not above 6 mL; may be diluted with saline); the vial is under nitrogen, so no vent needle is used and an equal volume of gas is withdrawn; swirl gently until dissolved and stand for 10 min. Technescan DMSA: 1-5 mL undiluted eluate, 1.2-3.7 GBq, invert, 15 min at room temperature. NephroScan: 5 mL, max 1.48 GBq, 10 min at 20-25 °C

Product: Renocis (UK SmPC, revizyon 04.02.2026); Technescan DMSA (İrlanda SmPC, Ekim 2024); NephroScan (ABD etiketi, DailyMed 29.09.2024); Ph. Eur. (PMC6166199)

Ph. Eur. ≥ 95%, free pertechnetate ≤ 2% (silica gel, methyl ethyl ketone)Renocis: 8 hours after labelling; Technescan DMSA and NephroScan: 4 hours (below 25 °C)
DTPA (pentetate)
Preparation

2-10 mL eluate, max 18.5 GBq; withdraw an equal volume of air, mix by inversion; stand 15 min before RCP; intravenous or inhaled by nebuliser

Product: Curium DTPA (ABD PI 2025); Ph. Eur. (PMC6166199)

Ph. Eur. ≥ 95%; US product ≥ 90% (ITLC-SG; saline and acetone)12 hours after preparation
Mebrofenin
Preparation

at most 5 mL eluate; shake; 30 min at room temperature (EU product)

Product: Choletec (ABD prospektüsü 2024); Pirot ve ark., Eur J Hosp Pharm 2024;31:376-380 (doi 10.1136/ejhpharm-2022-003512; AB ürünü Cholediam'ın hazırlık koşulları ve safsızlık sınırı)

impurities ≤ 5%, i.e. RCP ≥ 95% (limit as reported by Pirot 2024)Choletec: 18 hours after preparation (20-25 °C)
Sulphur colloid
Preparation

two-step with acid solution (A) and buffer (B); heat 5 min in a boiling bath or heating block (RCP falls with 3 min heating); do not use eluate with Al³⁺ above 10 µg/mL (a precipitate forms and may lodge in the lung); agitate the syringe gently just before injection

Product: ABD kit etiketi (DailyMed 2024); Michenfelder ve ark., J Nucl Med Technol 2014;42:283-288 (doi 10.2967/jnmt.114.145391)

≥ 92% bound (USP; 85% methanol, Whatman 31ET)in the product information

From the product information; the package insert of the product used at your institution is what counts. Preparation steps and products open under "Preparation" in each row.

Common mistakes

  • Exceeding the product's maximum activity or volume
  • Shaking MAA vigorously (foam, particle damage)
  • Starting the heating time before the water returns to the boil
  • Using old eluate, or eluate from a generator not eluted recently, in a kit that requires fresh eluate
  • Giving the dose without measuring RCP

Safety. Use a shielded vial and syringe; heat and cool inside the shield; monitor for contamination at the end of the work.

Sources: SmPC/prospektüs (aşağıdaki tablo) · EANM 2019 · IAEA TRS 466 (2008) kit üretimi · NANP MAA iyi uygulama (2016). Last reviewed: 23 November 2026.