血浆采样法测定GFR

清除率 = 给药量 / 曲线下面积;斜率-截距法(slope-intercept)漏掉早期分布成分,会高估GFR,需用Brøchner-Mortensen公式校正。

标题和摘要为机器辅助翻译(草稿);动画内容为英文。 英文完整页面 →

A GFR agent is injected into one arm and tubes are taken from the other arm at 120, 180 and 240 minutes; the area under the plasma concentration curve fills and clearance is computed as dose / area. In the second step the slope and intercept are drawn from the late samples on a log scale, the early area left out is shown, and the Brøchner-Mortensen correction is applied.

Continuous stream · no seeking

Key idea: clearance is dose / area under the curve; the slope-intercept method misses the early distribution component, overestimates GFR and is corrected with Brøchner-Mortensen.

Source: book (16.4: clearance = dose / area, slope-intercept with 2-4 samples, sampling from the other arm, Brøchner-Mortensen correction, Cr-51 EDTA, Tc-99m DTPA, when not to sample). Correction formula Brøchner-Mortensen 1972 (adults): Cl = 0.990778·Cl₁ − 0.001218·Cl₁². Dose and curve values are representative.

How to use: a single click on the drawing pauses and resumes; drag the time bar below to any moment; ← → change steps.

Did this animation help you understand the topic?