Radiation safety · 3 of 5
Segregation of radioactive waste and decay in storage
Awaiting physician review
To segregate radioactive waste by half-life and physical form, store it safely for decay and release it after measurement.
What you need
- Shielded, leak-tight, labelled waste containers (needles and syringes, vials, solid, biological)
- Plastic bags, labels, pen
- Locked, marked and ventilated interim waste store
- Surface contamination monitor
- Waste log
Steps
- Segregate waste where it is produced: by half-life (e.g. Tc-99m; I-123; I-131; Ga-67, In-111, Tl-201; Lu-177) and by form (needles and syringes, vials, gloves and covers, biological or infectious waste, linen).
- Put needles and syringes into the shielded sharps container in the room where they are produced; put gloves and covers into plastic bags.
- When a container or bag is full, close it; mark it with the radionuclide, date, container number and expected release date, and enter it in the log.
- Move the container to the interim waste store; keep containers separated by half-life group.
- Holding time: usually 10 half-lives of the longest-lived radionuclide (about 2.5 days for Tc-99m), or until the release criterion is met by measurement.
- Before release, survey the container in a low-background area, unshielded, on the most sensitive scale and over all its surfaces; it may be released if it cannot be distinguished from background.
- Remove or deface all radiation labels on released waste; dispose of it as biological or general waste according to its rules.
- Complete the release record: container number, survey date, result and background, instrument, person surveying.
Key points
- In the US only material with a half-life of no more than 120 days may be held for decay and disposed of as ordinary waste (10 CFR 35.92); the survey is done unshielded, on the most sensitive scale, at the surface. Türkiye (NDK Regulation on clearance and discharge of radioactive materials, Official Gazette 1.9.2023/32296): medical waste contaminated with radionuclides of half-life 100 days or less is held in durable bags for 10 half-lives of the longest-lived radionuclide in the bag and handed to an authorised medical waste facility; for longer-lived nuclides surface contamination must be below 0.4 Bq/cm² for beta-gamma and 0.04 Bq/cm² for alpha. Per sewer discharge each radionuclide may not exceed its exemption value (for mixtures the sum of ratios is at most 1 per discharge and 10 per month), at most 100 MBq per discharge and 100 GBq per year. In inpatient therapy wards patients' urine and faeces are held in a delay tank until below 100 Bq/L and until 10 half-lives of the longest-lived radionuclide have passed. The 2004 waste regulation (3.7 Bq/mL, 10 Bq/mL for I-131, 1 µSv/h at the bag surface) was repealed on 7.11.2023.
- Long-lived impurities are tracked separately: Lu-177m in carrier-added Lu-177, Ac-227 and Th-227 in Ra-223 (EANM 2022). Ge-68 (half-life 271 days) residues can accumulate and require long storage (IAEA SSG-46).
- For patient excreta IAEA SSG-46 generally prefers dilution in a continuous sewerage system to collecting and storing it; therapy wards may use delay tanks.
- A discharged therapy patient is told to flush the toilet after use, avoid splashing, clean the toilet and wash contaminated laundry separately.
- The origin of stored waste must be traceable from the records; the store's location and responsible person are written in the radiation protection programme.
Common mistakes
- Mixing different half-lives in one container
- Not marking the date and radionuclide
- Surveying through shielding or too quickly
- Disposing as general waste without removing labels
- Mixing Lu-177m waste with short-lived waste
Safety. Use shielded containers and keep sharps separate; keep the store locked; survey with gloves and keep it brief.
Sources: NDK Radyoaktif Maddelerin Serbestleştirilmesi ve Salımına İlişkin Yönetmelik (RG 1.9.2023/32296) md. 8 ve 15; Radyoaktif Atık ve Kullanılmış Yakıt Yönetimi Yönetmeliği (RG 7.11.2023/32362) · IAEA SSG-46 (2018), paras 4.274-4.281 · 10 CFR 35.92 (eCFR, 2026) · EANM Technologists' Guide: Radionuclide therapy management (2022), atık yönetimi. Last reviewed: 23 November 2026.