Radiation safety · 4 of 5

Personal dosimetry and ALARA

Awaiting physician review

To measure occupational dose reliably by wearing body and hand dosimeters in the right place and the right way, and to keep dose as low as reasonably achievable.

What you need

  • Body dosimeter (TLD, OSL or film)
  • Ring (extremity) dosimeter; eye lens dosimeter if needed
  • Electronic (active) dosimeter for therapy work
  • Dosimeter rack (in a low-background area)
  • Dose records

Steps

  1. Wear the body dosimeter on the trunk between collar and waist, with the labelled face outwards; wearing it near the collar is better for eye lens dose.
  2. If a lead apron is worn, the institution's programme states whether the dosimeter goes under or over it; follow it.
  3. Wear the ring dosimeter whenever you handle radiopharmaceuticals: unless the programme says otherwise, at the base of the index finger of the non-dominant hand, sensitive face towards the palm, under the glove.
  4. Dosimeters are used only at the institution that issued them; if you work at more than one, tell each of them.
  5. After work put dosimeters on the low-background rack; do not leave them in the hot lab, near patients or in the same cupboard as sources.
  6. Exchange dosimeters at the set interval (usually monthly); report a lost or contaminated dosimeter at once.
  7. Read the dose report; for a value above the investigation level (e.g. 0.5 mSv effective dose or 15 mSv finger dose per month) the radiation protection officer investigates the cause.
  8. ALARA: keep time short, increase distance (tongs, long-handled tools), use shielding (vial and syringe shields, lead glass); rehearse the task beforehand.

Key points

  • Occupational dose limits (IAEA GSR Part 3): effective dose 20 mSv per year averaged over 5 years, 50 mSv in any single year; lens of the eye 20 mSv per year averaged over 5 years, 50 mSv in any single year; skin and extremities 500 mSv per year. In Türkiye two texts differ: the NDK Radiation Safety Regulation (art. 10) gives effective dose 20 mSv averaged over 5 years, 50 mSv in any single year; hands, feet and skin 500 mSv; lens of the eye 150 mSv per year (the pre-ICRP 118 value). The Ministry of Health Nuclear Medicine Services Regulation (2023, art. 12) gives, for nuclear medicine centres, lens of the eye 20 mSv averaged over 5 years and at most 50 mSv in a single year; hands, arms, feet and skin 500 mSv. Under NDK rules the public limit applies to a pregnant worker's unborn child, and a breastfeeding worker is not assigned to work with a contamination risk (art. 12).
  • ORAMED study: a ring at the base of the index finger of the non-dominant hand reads on average 6 times lower than the maximum hand dose, so the reading is multiplied by 6 to estimate the maximum. Wrist dosimeters are not recommended (about 20 times lower).
  • For staff who always use shields and never touch the needle or vial, the fingertip / finger base ratio is lower (suggested correction 3; 4 in between; 6 otherwise); a personal correction can therefore be determined over a short measurement period.
  • Once a worker declares pregnancy, the embryo-fetus dose should not exceed 1 mSv for the rest of the pregnancy; for external exposure the fetal dose is usually below 25% of the body dosimeter reading (IAEA SSG-46).
  • Hand and eye lens monitoring is recommended when annual dose may exceed three-tenths of the limit: 150 mSv per year for hands and skin, 15 mSv in a single year for the eye lens (ISO 15382:2025).

Common mistakes

  • Wearing the ring over the glove or facing the wrong way
  • Leaving the dosimeter in the hot lab
  • Using another institution's dosimeter
  • Wearing the ring only for some tasks
  • Ignoring a high dose report

Safety. Time, distance, shielding; change a contaminated glove at once: skin contamination greatly increases finger dose.

Sources: NDK Radyasyon Güvenliği Yönetmeliği (RG 24.3.2000/23999; son değişiklik 28.10.2023/32353) md. 10, 12; Sağlık Bakanlığı Nükleer Tıp Hizmetleri Yönetmeliği (RG 25.4.2023/32171) md. 12 · IAEA GSR Part 3 (2014), Ek III doz sınırları · IAEA SSG-46 (2018), paras 4.117-4.149 · Sans-Merce ve ark., Radiat Meas 2011;46:1330-1333 (doi 10.1016/j.radmeas.2011.07.011) — ORAMED önerileri · Martin, J Radiol Prot 2016;36:405-418 (doi 10.1088/0952-4746/36/3/405, PMID 27340119) · ISO 15382:2025 · EANM Technologists' Guide: Radionuclide therapy management (2022), radyasyondan korunma. Last reviewed: 23 November 2026.