Administering I-131 therapy (capsule and liquid)
Awaiting physician review
To give the prescribed I-131 activity to the right patient while minimising the risk of volatilisation and contamination.
What you need
- Capsule vial in its lead pot, or liquid I-131
- Ventilated enclosure (fume hood)
- Decapping pliers, tongs, absorbent pad
- Dose calibrator (I-131 setting and a setting for this container geometry)
- Water, cup; double gloves, lab coat, dosimeter
- Contamination monitor, waste container
Steps
- Identify the patient; confirm written consent, the prescription (activity), preparation (overnight fasting), the pregnancy test (no more than 72 hours before), that breastfeeding stopped at least 6 weeks before, and that the waiting time after iodinated contrast or amiodarone has passed (times in the notes).
- Open the capsule vial in a fume hood without removing it from its shield: I-131 is volatile and its daughter Xe-131m is a gas.
- Assay the activity in the dose calibrator immediately before administration; compare with the prescription, ideally with two people verifying.
- Do not touch the capsule; transfer it from the vial directly into the patient's mouth or into a cup, and have the patient swallow it with water.
- Confirm that the patient has swallowed it; assay the empty vial and containers and record the residual.
- Liquid I-131 is used only in special situations such as swallowing difficulty and with suitable ventilation; contamination risk is higher than with capsules.
- The patient fasts for 1-2 hours after administration and is told to drink plenty and void often.
- Survey the area and your hands, segregate waste; give the patient written radiation protection instructions and plan the discharge measurement.
Key points
- EANM 2023 (benign thyroid) prefers the capsule: easier and safer, with lower contamination risk. The intravenous route can be used when the patient cannot take it orally; oral liquid is off-label in some countries.
- SNMMI 2012: precautions against volatilisation and inhalation during preparation and administration (fume hood, alkaline pH, giving the dose soon after preparation); activity verified in the dose calibrator, ideally by two people.
- Different vials, capsules and liquid volumes may need different calibrator settings; the institution's validated setting is used.
- Discharge limits vary by country (e.g. Australia: 25 µSv/h at 1 m). Türkiye (NDK Radiation Safety Regulation art. 31): a patient given up to 600 MBq may be discharged; at higher activities the patient stays in a separate room (above 800 MBq, an authority-approved isolation room with a liquid waste system) until the body activity is below 600 MBq and the dose rate at 1 m below 30 µSv/h; instructions are given in writing against signature, and administered and remaining activity and dose rate are recorded with the time.
- Waiting times differ by indication: in benign thyroid disease 6-8 weeks after water-soluble contrast, 3-6 months after lipophilic contrast, at least 6 months after amiodarone (EANM 2023); in differentiated thyroid cancer 4-6 weeks after contrast-enhanced CT (SNMMI/EANM 2022). The product information notes a risk of hyponatraemia (elderly, thiazides, after thyroidectomy); the physician assesses it.
Common mistakes
- Opening the vial in the open room
- Touching the capsule by hand
- Not assaying the activity before administration
- Not confirming identity and preparation
- Not recording the residual
Safety. Use a fume hood, double gloves and tongs; keep close contact time with the patient short; follow institutional instructions for thyroid protection in case of I-131 contamination.
Sources: NDK Radyasyon Güvenliği Yönetmeliği (RG 24.3.2000/23999; son değişiklik 28.10.2023/32353) md. 31 · EANM radyoiyot tedavisi (benign tiroid) kılavuzu (Eur J Nucl Med Mol Imaging 2023; doi 10.1007/s00259-023-06274-5) · SNMMI Practice Guideline for Therapy of Thyroid Disease with 131I 3.0 (2012) · SNMMI/EANM diferansiye tiroid kanseri işlem standardı (J Nucl Med 2022;63:15N-35N; PMID 35649660) · ANSTO Sodium Iodide [131I] Therapy Capsule ürün bilgisi (Avustralya, 2024) · EANM Technologists' Guide: Radionuclide therapy management (2022). Last reviewed: 23 November 2026.